JOSME Water-based Alkyd Coating is a water-based alkyd resin technology for anti-corrosion and finishing for metals. VOC <100 g/L Pencil hardness H-2H 60° gloss 80-90 GU A direct replacement for solvent based alkyd paint, providing steady Class 5B adhesion and basic anti-corrosion performance. Applicable to steel buildings, mechanical equipment and industrial vehicles
Traditional solvent-based alkyd paint employs organic solvents, emits significant odours and fire dangers and does not comply with modern environmental regulations.
This Water-based Alkyd Coating uses pure water instead of organic solvents. Alkyd resin is stably emulsified in water and cured by oxidative cross-linking, which reduces VOC emissions.
It has comparable levelling and high-gloss effect as solvent-based treatments with shorter drying time and lesser toxicity. Meet the mainstream environmental protection requirements, a feasible upgrade for the refurbishment of factories and new development.
| Property | Value / Standard |
|---|---|
| Film-forming Material | Water-based alkyd resin |
| VOC Content | Typically < 100 g/L |
| Gloss Level (60°) | 80–90 GU |
| Pencil Hardness (after full cure) | H–2H (ASTM D3363) |
| Adhesion (cross-hatch) | Class 5B (ASTM D3359) |
| Surface Treatment Grade | SA2.5 / ST3 |
| Application Temperature | ≥ 5°C |
| Max Application Humidity | ≤ 80% |
| Water Addition (dilution) | ≤ 10% |
| Application Method | Spray (recommended), roller, brush |
| Corrosion Environment | C2–C3 (ISO 12944) |
1. Environmentally friendly water-based formula
Deionised water carrier, free of mineral spirits, benzene and formaldehyde. VOC less than 100 g/L. EU Deco Directive and EPA limitations. Dilute with clean water max 10%.
2. Bonding & Glossy Finish
ASTM D3359 Class 5B adhesion. Friction resistant hardness H-2H. 80-90 GU gloss with improved levelling and reduced brush strokes.
3. Built-in Rust Resistance (Flash)
Oxidation during curing can be prevented by anti-rust additives, which can produce stable films even with changes in humidity and temperature.
Remove rust, scale and grease by sandblasting or polishing to SA2.5 / ST3. Spray to coat evenly. Roller/brush for touch-ups. Do not let the temperature drop below 5°C or humidity exceed 80%. Max dilution 10%.
General to moderate corrosion protection C2-C3 ISO 12944:
Steel constructions: C/H profiles, gantry cranes, mine props
Industrial machinery Speed reducers General equipment
Construction and agricultural machinery: earthmovers, trailers, agricultural vehicles
Industrial Equipment, Warehouse Frames, Factory Infrastructure
Can be applied straight as a topcoat and retains its oil and fuel resistance and colour. Technical team recommends as per project needs.

JOSME has a complete quality management system including inspection of raw materials, monitoring of production and testing of completed products. Each batch is evaluated for viscosity, particle size, anti-flash rust & drying cycle.
QUV weathering per ASTM G154 validates preservation of gloss and colour. Batch sampling offers uniformity from order to order.
Certifications: ISO 9001,14001,45001, 50001, China Environmental Labelling, China Green Water-based Alkyd Coating . Test reports and export papers upon request.

All export items are packed in reinforced ocean goods package to avoid leakage and damage during long distance shipping. Our standard goods ship in 2-3 business days. Private label orders and custom colour matching take 7-15 working days to produce.
We provide tailored services such as colour correction, particle size optimisation, private-label packaging, and formula modification for substrates and operating circumstances. We welcome customer inquiry for project price and customised scheme consultation.

Q1. What are the main changes compared with solvent based alkyd paint?
A1 : Water as diluent, without organic solvents or additional benzene/formaldehydes . Reduced VOC and odour, no flammability threat.
Q2. What is flash rust and why is anti flash rust important?
A2: Metal surface oxidation during evaporation of water-based coatings. The anti-flash rust formula avoids this fault and stabilises the quality of the film and reduces adhesion failure under fluctuating humidity and temperature.
Q3: Appropriate working settings and equipment?
A3: Steel structures, cranes, mining supports, construction machinery and agricultural vehicles in ISO 12944 C2–C3 mild corrosion conditions.
Q4: Will it work over old existing coatings?
A4: Good compatibility with typical metal coating methods. Make sure the substrate is clean, dry and free from loose layers. Our technical staff can help with multi-layer matching.
Q5: Do you need a surface pretreatment?
A5: Rust, oil and other impurities must be sandblasted or manually polished to the SA2.5 or ST3 level to allow efficient bonding.
For product parameter consultation, technical guidance, sample application and bulk procurement of Water-based Alkyd Coating, please get in touch with our team via [email protected].